Product information "Gold Plating Bath JE250 - 5 g/L Au"
The micron gold plating bath JE250 is suitable for an excellent deposition of bright and hard gold layers up to 8 µm. It is suitable for technical and decorative applications.
Operating data:
Gold content: 5 g/L Au
pH-value: 4,0 (3,8 - 4,2)
Density: 1,035 g/ml (1,030 - 1,050)
Deposition data:
Hardness: 150 - 220 HV
Layer thickness: max. 8 µm
Fineness of the gold layer: ca. 99,5 % Au
Operating conditions:
Voltage: 2,5 - 4 Volt
Temperature: 20 - 40 °C
Anodes: Platinized titanium
Anode/Cathode surface: approx. 1 : 1
Goods movement: required
Power density: approx. 1 - 2,5 A/dm2
Bath filtration: from 10 liter
Deposition rate: approx. 22 mg/Amin
Operating data:
Gold content: 5 g/L Au
pH-value: 4,0 (3,8 - 4,2)
Density: 1,035 g/ml (1,030 - 1,050)
Deposition data:
Hardness: 150 - 220 HV
Layer thickness: max. 8 µm
Fineness of the gold layer: ca. 99,5 % Au
Operating conditions:
Voltage: 2,5 - 4 Volt
Temperature: 20 - 40 °C
Anodes: Platinized titanium
Anode/Cathode surface: approx. 1 : 1
Goods movement: required
Power density: approx. 1 - 2,5 A/dm2
Bath filtration: from 10 liter
Deposition rate: approx. 22 mg/Amin
Hazard warnings
H314 Causes severe skin burns and eye damage.
H318 Causes serious eye damage.
H350i jentner.statements.H350i
H412 Harmful to aquatic life with long lasting effects.
Safety instructions
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301+330+331 jentner.statements.P301+330+331
P303+361+353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower.
P305+351+338 jentner.statements.P305+351+338
P310 Immediately call a POISON CENTER/doctor/…
P501.9 jentner.statements.P501.9